Energy efficiency · Industrial cooling

The cheapest energy is the energy you never use.

Cooler workshops, leaner chillers, lower bills. E2DP designs and delivers adiabatic cooling solutions for industrial and commercial sites, from the audit to the measured result.

up to −90 %energy vs air conditioning
100 %filtered fresh air
0refrigerant

Oxycom manufacturer data and published tests; to be confirmed by a study of your site.

The challenges

What is costing your site money

Four situations we see every summer. Click to learn more.

The solutions

Two Oxycom technologies, one principle: water instead of the compressor

Click to see how they work and where they apply.

Quick check

Is your site a good fit?

Tick what applies to your site. The more boxes you tick, the more likely the solution pays off.

Incentives, regulation and compliance

Why act now

The French framework has changed a lot since 2025. Here is what matters most for industrial and commercial sites, and how we help you respond.

Decree no. 2025-482

Heat at work

Since 1 July 2025, employers must include intense-heat risk in their risk assessment (DUERP), adapt processes, premises and work organisation, and provide technical protection. Météo-France yellow, orange and red alerts trigger these measures.

Adiabatic cooling sized for your workshops is a lasting technical answer.
Official text · Légifrance

General information as of September 2026, for guidance only. Applicability depends on each site's activity, floor area and consumption.

Technology references

Sites already using it

E2DP represents Oxycom technology, installed across Europe and worldwide for more than twenty years, including at Auchan in Hungary. Here is a selection of its most emblematic references, delivered by Oxycom.

In the field

Other Oxycom references in Europe: BMI-Thegon, PERFECT Van Wamel, Leeb Biomilch, Kruidvat…

The method

From audit to proof

Four steps, one deliverable at each. Click for details.

Who we are

Independent engineering, backed by manufacturers

The founder

Miguel Ángel Mendoza

Founder and Managing Director

An electronics engineer with a master's in finance and a European Energy Manager (EUREM), he has led Grupo EDP since 2015, a Mexican engineering group specialising in energy efficiency and building automation and winner of the 2022 ALAS Award.

Sixteen years of energy and critical infrastructure projects in Mexico. Now based in Toulouse, he founded E2DP to bring industrial and commercial sites technologies that cut both the bill and the carbon footprint. He works in English, French and Spanish.

EUREMALAS Award 2022EN · FR · ES
Miguel Ángel Mendoza

E2DP

An independent firm based in Toulouse. A single point of contact from audit to measured result, working in your site's interest rather than a machine's.

The manufacturers

We work hand in hand with the manufacturers whose technologies we represent, and with their backing. Oxycom's technical teams, who have designed and built its systems in the Netherlands for more than twenty years, support the engineering of every project.

The partners

Depending on the project, we team up with installers, engineering consultancies and complementary manufacturers. In Mexico, the Grupo EDP teams follow projects in Mexico.

Toulouse, France
Mexico City, Mexico
Grupo EDP track record

A few projects delivered in Mexico by the Grupo EDP teams under the founder's leadership.

Bank of Mexico Museum
Flagship · 2022 ALAS Award

Bank of Mexico Museum

Mexico City

Civil works, HVAC, data centre and 5 technical rooms in a heritage building.

Foro AztlánOngoing
Performance venue

Foro Aztlán

Chapultepec Park, Mexico City

About 2 MW (580 TR) of HVAC: hall, stage, lobbies and dressing rooms.

Campeche Light Rail
Public transport

Campeche Light Rail

Campeche

HVAC for the workshop, maintenance and control building, including the server room.

IMSS Hospital no. 69
Healthcare

IMSS Hospital no. 69

San Quintín, Baja California

LV/MV electrical (2 substations), HVAC, fire detection and CCTV.

Chalco – Santa Martha elevated trolleybus
Public transport

Chalco – Santa Martha elevated trolleybus

Valley of Mexico

Plumbing, stormwater and fire protection installations for the line.

National Housing Museum
Culture

National Housing Museum

Mexico City

Civil works, HVAC and specialist installations.

FAQ

Frequently asked questions

What is adiabatic cooling?

It works like sweat: as water evaporates, it absorbs heat from the air. IntrCooll does it in two stages. A heat exchanger first cools the air without adding moisture, then direct evaporation finishes the job. The supply air is cooler than with conventional evaporative cooling, and far less humid.

Does it use refrigerant?

No. IntrCooll has no compressor and no refrigerant: just water, air and fans. PreCooll doesn't replace your chiller; it pre-cools the air entering its condenser so it works less.

Does adiabatic cooling increase humidity?

Thanks to its indirect first stage, IntrCooll adds up to 70 % less moisture than direct evaporative cooling, keeping the indoor climate within ASHRAE guidance.

What about water consumption?

Up to 30 % lower than direct evaporative cooling, with a water quality sensor to avoid waste. A UV-C steriliser is available as an option.

Is maintenance easy?

Yes. It mainly means checking filters, cleaning the heat exchanger and monitoring water quality. The units are hygiene-certified to VDI 6022 and can be monitored remotely with OxyConnect.

Do we need to stop production to install?

No. Units sit on the roof or façade with three connections: water, drain and power. At 247TailorSteel, nine units were installed in one day.

Where do you work?

From Toulouse we cover France and Spain, and from Mexico City we support projects in Mexico and Latin America.

How do we start?

With a 30-minute call and a site visit. We come back with a costed simulation and, if it makes sense, a pilot proposal.

Contact

Let's talk about your site

Describe your installation and your need: workshop too hot, energy bill, chiller at its limit, regulatory obligation.

contact@e2dp.frWhatsApp · +33 7 45 71 28 11Toulouse, France · Mexico City, MexicoGrupo EDP

Your data is only used to answer your request. Legal notice and privacy

Flagship · Oxycom IntrCooll

Adiabatic cooling for workshops and warehouses

Filtered, cool fresh air across the whole building, using up to 90 % less energy than air conditioning.

IntrCooll units on a rooftop
IntrCooll units on a rooftopProject by: Oxycom

Water does the compressor's job. IntrCooll cools outdoor air in two stages: an indirect exchanger pre-cools it without adding moisture, then the Oxyvap evaporative media brings it to supply temperature, with a wet-bulb efficiency of up to 114 %.

Supply air is 100 % outdoor and filtered, pushing out heat, dust and process fumes instead of recirculating them. No compressors and no F-gases, just water and variable-speed EC fans with OxyLogic control, OxyConnect monitoring and Modbus integration with your BMS.

6,000 / 14,000 m³/hnominal airflow Std / Plus
1.29 / 3.35 kWnominal electrical power
up to 118 kWcooling per Plus unit at 46 °C
up to −7 °Ccompared with direct evaporative

Where it applies

Food processing, industrial bakeries, automotive, metalworking, plastics, printing, packaging, logistics.

Request an assessment
Oxycom PreCooll

Pre-cooling for chillers and data centres

A kit that cools air before the condenser: lower consumption, lower peaks, more capacity.

PreCooll in front of a data centre chiller
PreCooll in front of a data centre chillerProject by: Oxycom

PreCooll fits around the condenser of existing chillers and dry coolers. It pre-cools outdoor air by evaporation before it enters the machine, so the compressor works less, especially during heat peaks when the plant needs it most.

Media panels click in and out, with no work on the refrigerant circuit and no shutdown of the critical process. In a data centre, every kW saved on cooling is a kW freed for IT, and PUE improves directly.

up to −40 %cooling system consumption
+20 %cooling capacity
−14 %peak power
+24 to +39 %EER at full and part load

Where it applies

Data centres, industrial chillers, process cooling, retail.

Request an assessment
The challenges

Heat on the shop floor

Above 30 °C, fatigue, errors and breaks rise, followed by absenteeism and staff turnover. In a workshop with ovens, presses or motors, indoor temperatures often far exceed outdoor ones.

In France, since 1 July 2025 (decree no. 2025-482), employers must include intense-heat risk in their risk assessment and adapt processes, premises and work organisation, with technical protection.

Our answer

IntrCooll supplies filtered, cool fresh air throughout the space. At Bridgestone in Bari, the workshop reached 45 °C before 16 units were installed.

Request an assessment
The challenges

Bills and demand peaks

Cooling a large volume with compressors needs a lot of electrical power, ductwork, refrigerant and maintenance. And peak demand comes on the hottest days, with production running flat out.

Adiabatic cooling replaces the compressor with water evaporation: one IntrCooll Plus unit delivers up to 118 kW of cooling at 46 °C outdoors for 3.35 kW of nominal electrical power.

Our answer

On existing chillers, PreCooll cuts peak power by up to 14 % and cooling system consumption by up to 40 %.

Request an assessment
The challenges

Regulatory obligations

Reduction targets for commercial buildings, mandatory energy audits above 2.75 GWh a year, protecting workers from heat: regulation now requires measuring, planning and proving.

Cooling and air conditioning weigh heavily in these figures. Cutting them is often one of the fastest levers to pay back.

Our answer

We quantify each solution's impact on your consumption, ready for your action plan.

Request an assessment
The challenges

Refrigerants

Regulation (EU) 2024/573, known as F-Gas III, phases out hydrofluorocarbons (HFCs) until their elimination in 2050. Quotas are falling, and virgin high-GWP refrigerants (GWP ≥ 2,500) have been banned for servicing refrigeration equipment since 2025 and air conditioning since 2026, and placing-on-the-market bans for new equipment are staggered according to GWP.

Every new compression installation therefore carries cost and regulatory risk for the next twenty years.

Our answer

IntrCooll uses no refrigerant, just water and air. PreCooll relieves and extends existing chillers.

Request an assessment
How this figure is obtained

Up to 90 % less energy

IntrCooll replaces the air-conditioning compressor with water evaporation. It only uses power for the fans and pump: one IntrCooll Plus unit delivers up to 118 kW of cooling at 46 °C outdoors for 3.35 kW of nominal power.

In the field: −90 % at Sinnack, −85 % at Auchan, −80 % at Neuman Aluminium.

Oxycom data, compared with compression air conditioning at the same airflow. Actual savings depend on climate, building and operating hours.

How this figure is obtained

Up to 40 % savings on chillers

PreCooll cools the air before it enters the condenser of a chiller or dry cooler. The compressor runs at a lower condensing pressure and uses less power, especially during heat peaks.

Trane lab test for Equinix at 34 °C and 60 % humidity: −10 % absorbed power and EER improved by 24 to 39 %.

Oxycom data. Annual savings depend on climate, load profile and chiller condition.

How this figure is obtained

+20 % cooling capacity

In hot weather an air-cooled chiller loses part of its capacity. By lowering the condenser air temperature, PreCooll gives it back: enough to ride out peaks without adding a machine.

Trane test for Equinix: cooling capacity rose from 778 to 872 kW under the same conditions.

Oxycom data; the gain varies with the chiller model and outdoor conditions.

How this figure is obtained

2 to 4 years payback

This is the range Oxycom quotes for PreCooll. For IntrCooll, the comparison is with the purchase and running cost of conventional air conditioning, or with the cost of heat: absenteeism, scrap, machine downtime.

Every project starts with a simulation using your city's climate data and your electricity tariff.

Indicative: actual payback depends on the site, operating hours and available incentives.

The method · 01

Audit

Site visit, survey, bills, load profiles and site constraints.

A site visit to record floor area, height, process heat load, existing extraction, operating hours and connection points. We also review your bills and any temperature readings.

DeliverableSite survey and first findings
Request an assessment
The method · 02

Simulation

Sizing with your city's climate data, scenarios and payback.

We size with your city's climate data: number of units, airflow, supply temperature at the hottest hours, consumption and payback, compared with conventional air conditioning.

DeliverableSizing note and costing
Request an assessment
The method · 03

Pilot

Start on one area or machine and measure the real result.

To remove any doubt we start with one area or machine. Temperatures and consumption are measured before and after.

DeliverableBefore / after measurements
Request an assessment
The method · 04

Roll-out

Extend to the whole site, commission and track performance.

Roll-out across the site with the installer, commissioning, tuning and remote monitoring via OxyConnect. We track performance over time.

DeliverableCommissioning and follow-up
Request an assessment
Retail · IntrCooll

Auchan

Soroksár (Budapest), Hungary

Project by Oxycom partner: Oxyma Systems

Context

A hypermarket on the outskirts of Budapest with nine ageing rooftop HVAC units (COP 2.0 to 2.5), temperature-sensitive fresh produce aisles and a mandatory energy-reduction target to meet.

Solution

Old HVAC units replaced with Oxycom's Rooftop Retrofit, based on IntrCooll technology.

Results

−85 %energy for cooling and ventilation
365 tless CO₂ per year
−40 %food waste, with fruit and vegetables staying fresh longer

Source: Oxycom.

E2DP represents Oxycom technology, installed across Europe and worldwide for more than twenty years, including at Auchan in Hungary.

Metals · extrusion · IntrCooll

Neuman Aluminium

Marktl, Austria

Neuman Aluminium · Marktl, Austria
Neuman Aluminium · Marktl, AustriaProject by Oxycom partner: Infranorm

Context

Aluminium extrusion and machining generate intense heat: 32 °C measured in the hall, intolerable for operators.

Solution

IntrCooll two-stage adiabatic system installed by Oxycom partner Infranorm, replacing a 367 kW chiller.

Results

−80 %energy consumption
−71 %operating costs
< 25 °Cin the hall with 36.7 °C outside
98,000 m³/hfiltered fresh air

Source: Oxycom case study.

E2DP represents Oxycom technology, installed across Europe and worldwide for more than twenty years, including at Auchan in Hungary.

Industrial bakery · IntrCooll

Sinnack

Bocholt, Germany

Project by: Oxycom

Context

An industrial bakery with 30 baking lines and extreme internal heat; the old direct evaporative coolers added too much humidity.

Solution

15 IntrCooll units installed in 2017 in the three main halls, followed by extensions: 60 units today for comfort, spot and process cooling.

Results

60IntrCooll units
−90 %energy on process cooling

Source: Oxycom case study.

E2DP represents Oxycom technology, installed across Europe and worldwide for more than twenty years, including at Auchan in Hungary.

Industry · logistics · IntrCooll

Canon Production Printing

Netherlands

Project by Oxycom partner: Croonwolter&dros

Context

Poorly insulated 1980s halls: in 2019, 150 hours above the internal 25 °C limit.

Solution

16 rooftop IntrCooll units installed in summer 2020 by Croonwolter&dros, after noise tests because the site borders a residential area.

Results

16IntrCooll units
−10 °Cin the halls vs outdoors
100 %fresh air

Source: Oxycom case study.

E2DP represents Oxycom technology, installed across Europe and worldwide for more than twenty years, including at Auchan in Hungary.

Automotive · IntrCooll

Toyo Seat Europe

Százhalombatta, Hungary

Project by Oxycom partner: Oxyma Systems

Context

A 50 × 60 m production hall with welding: above 30 °C every summer, with dust and fumes.

Solution

6 IntrCooll units with HydroBank water treatment, installed by Oxyma Systems, Oxycom's Hungarian distributor.

Results

−84 %operating costs
< 25 °Cin summer, down from over 30 °C

Source: Oxycom case study.

E2DP represents Oxycom technology, installed across Europe and worldwide for more than twenty years, including at Auchan in Hungary.

Food packaging · IntrCooll

Plastic Legno

Italy

Project by Oxycom partner: Cleverclima

Context

A plastic tray factory where indoor temperatures ran 10 °C above outdoors in summer.

Solution

12 IntrCooll systems installed in 2019 and 2020 with Cleverclima, Oxycom's Italian partner.

Results

−81 %energy vs conventional AC
12IntrCooll units

Source: Oxycom case study.

E2DP represents Oxycom technology, installed across Europe and worldwide for more than twenty years, including at Auchan in Hungary.

Automotive · IntrCooll

Bridgestone

Bari, Italy

Bridgestone · Bari, Italy
Bridgestone · Bari, ItalyProject by Oxycom partner: CleverClima

Context

Indoor temperatures at this plant reached 45 °C in summer.

Solution

16 IntrCooll units cooling work areas with filtered fresh air.

Results

16IntrCooll units
45 °Cindoor temperature before the project
100 %filtered outdoor air

E2DP represents Oxycom technology, installed across Europe and worldwide for more than twenty years, including at Auchan in Hungary.

Metalworking · IntrCooll

247TailorSteel

Netherlands

247TailorSteel · Netherlands
247TailorSteel · NetherlandsProject by: Oxycom

Context

A made-to-measure sheet metal manufacturer with large production halls.

Solution

29 IntrCooll units; nine were installed on the roof in a single day.

Results

29IntrCooll units
1 dayto install 9 units on the roof

E2DP represents Oxycom technology, installed across Europe and worldwide for more than twenty years, including at Auchan in Hungary.

Data centres · PreCooll

Equinix

Amsterdam and London

Equinix · Amsterdam and London
Equinix · Amsterdam and LondonProject by: Oxycom

Context

One of the world's largest data centre operators needed more cooling without more energy, under Amsterdam's consumption restrictions.

Solution

14 PreCooll systems installed with Trane on existing backup chillers across three hubs, without compromising reliability.

Results

+12 %capacity at full load (778 → 872 kW)
−10 %maximum power draw at full load
+24 %EER at full load, +39 % at part load

Tested at Trane's Paris laboratory at 34 °C and 60 % RH. Later replicated in London.

E2DP represents Oxycom technology, installed across Europe and worldwide for more than twenty years, including at Auchan in Hungary.

Industrial bakery · IntrCooll Plus

Grupo Bimbo

Mexicali, Mexico

Project by: Oxycom

Context

A bakery plant on Mexico's northern border, with 45–50 °C outdoors and ovens running continuously.

Solution

20 IntrCooll Plus units in production, oven areas and storage, with heat recovery modules for year-round operation.

Results

20IntrCooll Plus units
14,000 m³/hfresh air per unit
Year-roundwith the Heat Reclaim module

E2DP represents Oxycom technology, installed across Europe and worldwide for more than twenty years, including at Auchan in Hungary.

Life sciences · IntrCooll

MilliporeSigma

California, USA

MilliporeSigma · California, USA
MilliporeSigma · California, USAProject by Oxycom partner: Gradd

Context

A large distribution centre to cool.

Solution

12 IntrCooll units bringing cool fresh air to the whole building.

Results

12IntrCooll units
168,000 m³/hfiltered fresh air

E2DP represents Oxycom technology, installed across Europe and worldwide for more than twenty years, including at Auchan in Hungary.

Food · IntrCooll

Galletas Dondé

Mexico

Project by: Oxycom

Context

Packaging and dough production areas with 38 °C outdoors.

Solution

22 IntrCooll units in packaging and production.

Results

22IntrCooll units
38 °Cdesign outdoor temperature

E2DP represents Oxycom technology, installed across Europe and worldwide for more than twenty years, including at Auchan in Hungary.

Food · IntrCooll

Dengo Chocolates

São Paulo, Brazil

Project by: Oxycom

Context

Oxycom's first project in Brazil, in chocolate production.

Solution

Adiabatic cooling with 24/7 remote monitoring.

Results

11.8 °Cmeasured temperature differential
24 / 7remote monitoring

E2DP represents Oxycom technology, installed across Europe and worldwide for more than twenty years, including at Auchan in Hungary.

Food · retail · IntrCooll

Almarai · eXtra

Saudi Arabia

Almarai · eXtra · Saudi Arabia
Almarai · eXtra · Saudi ArabiaProject by Oxycom partner: Dosan

Context

Sites in an extreme climate, where conventional air conditioning is very costly.

Solution

Adiabatic cooling instead of compression air conditioning.

Results

up to −70 %operating costs at Almarai
−54 %net costs at eXtra

E2DP represents Oxycom technology, installed across Europe and worldwide for more than twenty years, including at Auchan in Hungary.